Certification Manual
- 83 -
confirm. Note, to turn the pager on, simply press and hold the “Read”
button, until the startup text appears.
For more in depth features and settings, please refer to the manufacturer’s
manual.
Field Programming
In order to access the field programming screen, remove the battery
than re-insert it while holding the function button. (middle button) Continue
to hold down the button until the four zeros appear. Press the “Function”
button to change the digits and use the “Select” buttons to move between
the fields. The password is typically 2554, but it can be set by using the
USB programmer. (Refer to the Programming Guide in Appendix C) The
first feature that appears in the programming screen is the capcodes. To
change the capcodes, toggle through the fields with the “Select” buttons.
To change a field, press the “Function” Button. To move to the next
programming feature, press the “Read” button. The following features are
programmable in the field programming mode.
Capcodes 1-6 (the capcodes can be toggled on/off and the numbers
can be changed
Baud Rate (Typically set to 512)
Screen Contrast (Leave at default)
All other features must be programmed via the USB programmer